Quality Assurance Plan on a Linear Accelerator (LINAC) Plane on Nasopharynx Cancer (NFC) by using Prowess Panther 5.10 at Radiotherapy Installation Ken Saras Hospital

Pandu Kurnianto, Giner Maslebu, Jodelin Muninggar, Muhammad Hidayatullah

Abstract


Radiotherapy is the treatment of cancer by using electromagnetic and particle radiation. Nasopharyngeal Cancer (NPC) is one of the difficult case to be treated in radiotherapy because its anatomical location. Precision of radiation dose is part of Quality Assurance Program as the key factor in this treatment. Thus, it is very important to ensure that the output dose of Linear Accelerator (LINAC) matched with result of Treatment Planning System (TPS). This study used Siemens LINAC Type Primus MACH Series 5633 and a set of detectors for Nasopharynx Cancer analysis with 8 field. The total dose of 5,000 cGy divided into 25 fractions with 200 cGy dose per fraction. The 8 fields are irradiated with a target on a detector device. It is then accumulated with PTW-Verisoft software by plotting the results obtained from the detector tool with PTW (phantom) which we have CT Scanned first in PTW-Verisoft. From the total detectors exposed to the radiation, the detector corresponding to PTW is 372 detectors (100%) with unsuitable detector of 0 detectors (0.00%). It is proved that the planning is 100% match for NPC with 8 fields of radiation. Thus, this method is recomended to be implemented for NPC treatment

Keywords


Quality Assurance, Treatment Planning System, Nasopharyngeal Cancer, Radiotherapy

Full Text:

PDF

References


Gianfaldoni, S., Gianfaldoni, R., Wollina, U., Lotti, J., Tchernev, G., & Lotti, T. (2017). An Overview on Radiotherapy: From Its History to Its Current Applications in Dermatology. Open access Macedonian journal of medical sciences, 5(4), 521–525. https://doi.org/10.3889/oamjms.2017.122

Sembiring Depari.F.P.(2001). Cavita Slecta Radioterapi Semarang : RSUP Dr. Kariadi.

Evelyn C. Pearce. (2009) Anatomi dan Fisiologi. Jakarta : PT Gramedia.

Jicman Stan, D., Niculet, E., Lungu, M., Onisor, C., Rebegea, L., Vesa, D., Bezman, L., Bujoreanu, F. C., Sarbu, M. I., Mihailov, R., Fotea, S., & Tatu, A. L. (2022). Nasopharyngeal carcinoma: A new synthesis of literature data (Review). Experimental and therapeutic medicine, 23(2), 136. https://doi.org/10.3892/etm.2021.11059

Rueda Domínguez, A., Cirauqui, B., García Castaño, A., Alvarez Cabellos, R., Carral Maseda, A., Castelo Fernández, B., Iglesias Rey, L., Rubió-Casadevall, J., Arrazubi, V., & Mesía, R. (2022). SEOM-TTCC clinical guideline in nasopharynx cancer (2021). Clinical & translational oncology: official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico, 24(4), 670–680. https://doi.org/10.1007/s12094-022-02814-x

Dr. G. Tambunan.(1991). Sepuluh Jenis Kanker Terbanyak di Indonesia, Buku Kedokteran

Pari Pusat. (2016). Protokol Radiologi. Magelang:Inti Medika Pustaka.

Smilowitz, J. (2021), Khan's The Physics of Radiation Therapy, 6th Edition. Gibbons, John P., Author. Wolters Kluwer Health, Lippincott Williams & Wilkins, Baltimore and Philadelphia, 2019. ISBN: 9781496397522 . Med. Phys., 48: e771-e771. https://doi.org/10.1002/mp.14575

Zayat, D. , Attalla, E. , Abouelenein, H. , Elkem, Y. and Khalil, W. (2014) Dosimetric Comparison of Intensity-Modulated Radiotherapy versus Three-Dimensional Conformal Radiotherapy for Patients with Brain Tumors. Open Journal of Radiology, 4, 85-96. doi: 10.4236/ojrad.2014.41011.

El-Ghoneimy, E.G., Hassan, M.A., El-Bestar, M.F. et al. A dosimetric comparative study between conformal and intensity modulated radiation therapy in the treatment of primary nasopharyngeal carcinomas: the Egyptian experience. Chin. -Ger. J. Clin. Oncol. 11, 626–631 (2012). https://doi.org/10.1007/s10330-012-1040-7

Sahoo, Suvendu Kumar. (2016). Study a variation of Quality Assurance data of a LINAC after thirteen years operation for cancer treatment. European Journal of Pharmaceutical & Medical Research.

Iskandar. (2007). Analisis dosis radiasi kanker nasofaring dengan menggunakan wedge pada pesawat Linac. Makasssar: Universitas Hasanuddin.

Nasakha. (2010). Evaluasi stabilitas pesawat Accelerator Linear medik: BATAN.

Wang, R, Kang, M. Guidelines for radiotherapy of nasopharyngeal carcinoma. Prec Radiat Oncol. (2021); 5: 122– 159. https://doi.org/10.1002/pro6.1123

Bosse, C., Narayanasamy, G., Saenz, D., Myers, P., Kirby, N., Rasmussen, K., Mavroidis, P., Papanikolaou, N., & Stathakis, S. (2020). Dose Calculation Comparisons between Three Modern Treatment Planning Systems. Journal of medical physics, 45(3), 143–147. https://doi.org/10.4103/jmp.JMP_111_19

Ng, W.T.; Chow, J.C.H.; Beitler, J.J.; Corry, J.; Mendenhall, W.; Lee, A.W.M.; Robbins, K.T.; Nuyts, S.; Saba, N.F.; Smee, R.; et al. Current Radiotherapy Considerations for Nasopharyngeal Carcinoma. Cancers (2022), 14, 5773. https://doi.org/ 10.3390/cancers14235773

Thawites David. Accuracy required and achievable in radiotherapy dosimetry: have modern technology and techniques changed our views?, (2013) J. Phys.: Conf. Ser. 444 012006; doi:10.1088/1742-6596/444/1/012006




DOI: https://doi.org/10.26877/asset.v5i2.15247

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

SLOT GACOR
https://kampus.lol/halowir/
https://vokasi.unpad.ac.id/gacor/?ABKISGOD=INFINI88 https://vokasi.unpad.ac.id/gacor/?ABKISGOD=FREECHIPS https://vokasi.unpad.ac.id/gacor/?ABKISGOD=DATAHK https://vokasi.unpad.ac.id/gacor/?ABKISGOD=TOTO+4D

https://build.president.ac.id/

https://build.president.ac.id/modules/

https://build.president.ac.id/views/

https://yudisium.ft.unmul.ac.id/pages/

https://yudisium.ft.unmul.ac.id/products/

https://yudisium.ft.unmul.ac.id/data/

https://ssstik.temanku.okukab.go.id/

https://snaptik.temanku.okukab.go.id/

https://jendralamen168.dinsos.banggaikab.go.id/gacor/

https://dinsos.dinsos.banggaikab.go.id/

https://kema.unpad.ac.id/wp-content/bet200/

https://kema.unpad.ac.id/wp-content/spulsa/

https://kema.unpad.ac.id/wp-content/stai/

https://kema.unpad.ac.id/wp-content/stoto/

Advance Sustainable Science, Engineering and Technology (ASSET)

E-ISSN: 2715-4211
Published by Science and Technology Research Centre

Universitas PGRI Semarang, Indonesia

Website: http://journal.upgris.ac.id/index.php/asset/index 
Email: asset@upgris.ac.id